Standard Features
102 Basler scout light
Setting the Gain (slA750-60fm Only)
The camera’s gain is determined by the value of the Gain Raw parameter. Gain Raw is adjusted on
a decimal scale. The range for the Gain Raw parameter setting is from 0 to 22.
To set the Gain Raw parameter value:
Set the Gain Selector to Gain All.
Set the Gain Raw parameter to your desired value.
You can set the Gain Selector and the Gain Raw parameter value from within your application
software by using the pylon API. The following code snippet illustrates using the API to set the
selector and the parameter value:
Camera.GainSelector.SetValue( GainSelector_All );
Camera.GainRaw.SetValue( 20 );
For detailed information about using the pylon API, refer to the Basler pylon Programmer’s Guide
and API Reference.
You can also use the Basler pylon Viewer application to easily set the parameters.
For more information about the pylon Viewer, see Section 3.1 on page 17.
Note
The information in this section only applies to slA750-60fm cameras. For
information about the other camera models, see the previous section.