1.4 Environmental Requirements
1.4.1 Temperature and Humidity
Housing temperature during operation: 0 °C ... + 50 °C (+ 32 °F ... + 122 °F)
Humidity during operation: 20 % ... 80 %, relative, non-condensing
Housing temperature during storage: -20 °C ... + 80 °C (- 4 °F ... + 176 °F)
Humidity during storage: 5 % ... 95 %, relative, non-condensing
1.4.2 Ventilation
Allow sufficient air circulation around the camera to prevent internal heat build-up in your system
and to keep the camera housing temperature during operation below 50 °C. Provide additional
cooling such as fans or heat sinks if necessary.
1.5 Precautions
To ensure that your warranty remains in force:
Powerrr
Warning!
Without sufficient cooling, the camera can get hot enough during opera-
tion to cause burning when touched.
Caution!
Be sure that all power to your system is switched off before you make or break
connections to the camera. Making or breaking connections when power is on
can result in damage to the camera.
Caution!
The camera has no overvoltage protection. An input voltage higher than
14 VDC will damage the camera.
Caution!
Do not reverse the polarity of the input power to the camera. Reversing the
polarity of the input power can severely damage the camera and leave it non-
operational.