Basler A202k User Manual Page 57

  • Download
  • Add to my manuals
  • Print
  • Page
    / 118
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 56
Operation and Features
BASLER A202
k 3-27
DRAFT
3.7.1 AOI Setup Guidelines
When setting up the area of interest, several guidelines must be followed. The setup rules are
listed below.
The starting line must be an odd numbered line and the starting column must be an odd num-
bered column.
The number of columns included in the AOI must be divisible by 2 the number of lines
included in the AOI must be divisible by 2.
The sum of the setting for the Starting Column plus the setting for the Width in Columns can
not exceed 1005.
The sum of the setting for the Starting Line plus the setting for the Height in Lines can not
exceed 1005.
In normal operation, the camera is set to use all of the pixels in the array. To use all of the pixels,
the starting column should be set to 1, the width in columns should be set to 1004, the starting line
should be set to 1, and the height in lines should be set to 1004.
3.7.2 Changes to the Maximum Frame Rate with Area of Interest
When the area of interest feature is used, the camera’s maximum allowed frame rate increases.
The amount that the maximum frame rate increases depends on the number of lines included in
the area of interest. The smaller the number of lines in the area of interest, the higher the
maximum frame rate. The maximum allowed frame rate can be calculated using the following
formula:
Where: LI = the number of lines included in the area of interest
Maximum Frames per Second
1,000,000 µs
(LI x 20.55 µs) [ (1004 - LI) x 7.3 µs ] 204.8 µs++
-----------------------------------------------------------------------------------------------------------------------------------=
Page view 56
1 2 ... 52 53 54 55 56 57 58 59 60 61 62 ... 117 118

Comments to this Manuals