Acquisition Control AW00118302000
98 Basler racer GigE
Fig. 29: Use Case 2 - Continuous Frame Mode with Acquisition Start, Frame Start and Line Start Triggering Set to
Off
Time
Acquisition
start
command
Acquisition
stop
command
Frame start
trigger signal
Line start
trigger signal
Settings:
Acquisition Mode = Continuous Frame
Acquisition Start Trigger Mode = Off
Frame Start Trigger Mode = Off
Lines Per Frame (Height) = 3
Line Start Trigger Mode = Off
= trigger signal internally generated by the camera; trigger wait signal is not available
= line exposure and readout; white horizontal ruling: period used for exposure and exposure overhead
= complete frame transmitted
= partial frame transmitted
Page view 107