Acquisition Control AW00118302000
110 Basler racer GigE
Fig. 35: Use Case 8 - Continuous Frame Mode with Acquisition Start Triggering Set to On and Frame Start and Line
Start Triggering Set to Off
Time
Acquisition
start
command
Acquisition
stop
command
Acquisition start
trigger signal
Frame start
trigger signal
Line start
trigger signal
Settings:
Acquisition Mode = Continuous Frame
Acquisition Start Trigger Mode = On
Acquisition Start Trigger Source = 1
Acquisition Start Trigger Activation = Rising Edge
Acquisition Frame Count = 2
Frame Start Trigger Mode = Off
Lines Per Frame (Height) = 3
Line Start Trigger Mode = Off
= trigger signal internally generated by the camera; trigger wait signal is not available
= trigger signal applied by the user
= camera is waiting for an acquisition start trigger signal
= line exposure and readout; white horizontal ruling: period used for exposure and exposure overhead
= frame transmitted