Basler raL2048-48gm User Manual Page 91

  • Download
  • Add to my manuals
  • Print
  • Page
    / 238
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 90
AW00118302000 Acquisition Control
Basler racer GigE 81
Software - When the acquisition start trigger source is set to software, the user applies an
acquisition start trigger to the camera by issuing an acquisition start TriggerSoftware command
to the camera from the host PC.
Line 1, line 2 or line 3 - When the acquisition start trigger source is set to line 1, line 2 or line 3,
the user applies an acquisition start trigger to the camera by injecting an externally generated
acquisition start trigger signal (referred to as an ExASTrig signal) into physical input line 1, line
2 or line 3 on the camera.
If the Acquisition Start Trigger Source parameter is set to Line 1, Line 2 or Line 3, the user must also
set the Acquisition Start Trigger Activation parameter. The available settings for the Acquisition Start
Trigger Activation parameter are:
Rising Edge - specifies that a rising edge of the hardware trigger signal will act as the
acquisition start trigger.
Falling Edge - specifies that a falling edge of the hardware trigger signal will act as the
acquisition start trigger.
8.2.2.3 Acquisition Frame Count
When the Trigger Mode parameter for the acquisition start trigger is set to on, you must set the value
of the camera’s Acquisition Frame Count parameter. The value of the Acquisition Frame Count can
range from 1 to 65535.
With acquisition start triggering on, the camera will initially be in a "waiting for acquisition start
trigger" acquisition status. When in this acquisition status, the camera cannot react to frame start
trigger signals. If an acquisition start trigger signal is applied to the camera, the camera will exit the
"waiting for acquisition start trigger" acquisition status and will enter the "waiting for frame start
trigger" acquisition status. It can then react to frame start trigger signals. When the camera has
received a number of frame start trigger signals equal to the current Acquisition Frame Count
parameter setting, it will return to the "waiting for acquisition start trigger" acquisition status. At that
point, you must apply a new acquisition start trigger signal to exit the camera from the "waiting for
acquisition start trigger" acquisition status.
When the Acquisition Start Trigger Mode parameter is set to on, the camera’s
Acquisition Mode parameter must be set to continuous.
Page view 90
1 2 ... 86 87 88 89 90 91 92 93 94 95 96 ... 237 238

Comments to this Manuals