Acquisition Control AW00118302000
112 Basler racer GigE
Fig. 36: Use Case 9 - Continuous Frame Mode with Acquisition Start and Line Start Triggering Set to On and Frame
Start Triggering Set to Off
Time
Settings:
Acquisition Mode = Continuous Frame
Acquisition Start Trigger Mode = On
Acquisition Start Trigger Source = 1
Acquisition Start Trigger Activation = Rising Edge
Acquisition Frame Count = 2
Frame Start Trigger Mode = Off
Lines Per Frame (Height) = 3
Line Start Trigger Mode = On
Line Start Trigger Source = Line 3
Line Start Trigger Activation = Rising Edge
Acquisition start
trigger signal
Frame start
trigger signal
Line start
trigger signal
= trigger signal internally generated by the camera; trigger wait signal is not available
= trigger signal applied by the user
= camera is waiting for an acquisition start trigger signal
= camera is waiting for a line start trigger signal
= line exposure and readout; white horizontal ruling: period used for exposure and exposure overhead
= line start trigger signal is ignored because the camera is waiting for an acquisition start trigger signal
= complete frame transmitted
= partial frame transmitted
Acquisition
start
command
Acquisition
stop
command