Basler raL2048-48gm User Manual Page 121

  • Download
  • Add to my manuals
  • Print
  • Page
    / 238
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 120
AW00118302000 Acquisition Control
Basler racer GigE 111
Use Case 9 - Acquisition Start and Line Start Triggering On,
Frame Start Triggering Off (Free Run)
Use case nine is illustrated on page 133.
In this use case, the Acquisition Start Trigger Mode and the Line Start Trigger Mode parameters are
set to on, requiring that an acquisition start and a line start trigger signal are applied to the camera.
The Frame Start Trigger Mode parameter is set to off. The camera will internally manage frame start
signals without any need for triggering by the user ("free run").
In this example, Acquisition Frame Count is set to two. Accordingly, two consecutive frames will be
acquired for each transition of the acquisition start trigger signal.
The rate at which the camera will acquire lines will be determined by the line start trigger signal and
must be below the maximum allowed line rate determined by the current setting. Note that the
overall line rate will also depend on the acquisition start trigger signal: Lines will only be acquired
after a related preceding transition of the acquisition start trigger signal has occurred.
In this example, each frame is set to include three lines.
When the Acquisition Mode is set to Continuous Frame, the camera will be set to acquire frames
until an acquisition stop command is issued.
Page view 120
1 2 ... 116 117 118 119 120 121 122 123 124 125 126 ... 237 238

Comments to this Manuals

No comments