Basler raL2048-48gm User Manual Page 133

  • Download
  • Add to my manuals
  • Print
  • Page
    / 238
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 132
AW00118302000 Acquisition Control
Basler racer GigE 123
8.3.1 Exposure Active Signal
The camera’s Exposure Active output signal will go high when the exposure time for each line
acquisition begins and goes low when the exposure time ends. An example of the Exposure Active
signal’s behavior on a camera using a rising edge external line start trigger signal (ExLSTrig) and
the timed exposure mode is shown in Fig. 44.
Fig. 44: Exposure Active Signal
By default, the Exposure Active signal is selected as the source signal for output line 1 on the
camera. However, the selection of the source signal for a physical output line can be changed.
For more information about selecting the source signal for an output line on the camera, see
Section 7.6.2.5 on page 68.
For more information about the electrical characteristics of the camera’s output lines, see
Section 7.6.2.1 on page 64.
Exposure
Line N
Exposure
Line N+1
Exposure
Line N+2
ExLSTrig
Signal
Exposure
Active Signal
Not to scale
Page view 132