AW00118302000 Acquisition Control
Basler racer GigE 101
Use Case 4 - Acquisition Start Triggering Off (Free Run), Frame Start and
Line Start Triggering On
Use case four is illustrated on page 123.
In this use case, the Acquisition Start Trigger Mode parameter is set to off. The camera will internally
manage acquisition start trigger signals without any need for triggering by the user ("free run").
The Frame Start Trigger Mode and the Line Start Trigger Mode parameters are set to on, requiring
that frame start and line start trigger signals are applied to the camera.
The rate at which the camera will acquire lines will be determined by the line start trigger signal and
must be below the maximum allowed line rate determined by the current setting. Note that the
overall line rate will also depend on the frame start trigger signal: Lines will only be acquired after a
related preceding transition of frame start trigger signal has occurred.
In this example, each frame is set to include three lines.
When the Acquisition Mode is set to Continuous Frame, the camera will be set to acquire frames
until an acquisition stop command is issued.