AW00118302000 Acquisition Control
Basler racer GigE 119
Fig. 42: Relation of the ExLSTrig Signal Period and Periods E and F for Regular Line Acquisition in Timed Exposure
Mode
Fig. 43: Relation of the ExLSTrig Signal Period and Periods E and F for Regular Line Acquisition in Trigger Width
Exposure Mode
From the above conditions, one can readily calculate the allowed values for E and F for regularly
operating the camera at the maximum allowed line rate. This operation will also involve the
maximum possible overlap between consecutive line acquisitions.
When you want to operate the camera at the maximum allowed line rate and
have set the ExposureOverlapTimeMax parameter value to the appropriate
value (see above) you can vary the exposure time E within the ranges
indicated in Table 11 without having to adjust the ExposureOverlapTime Max
parameter value.
ExLSTrig Signal Period (= Line Acquisition Period = 1/Line Rate)
ExLSTrig
Signal
E: Exposure
Determined by the Exposure Time
Parameter or Register Setting
F: Exposure Overhead or
Exposure Overhead &
(at Least Partial) Readout
ExLSTrig
Signal
ExLSTrig Signal Period (= 1/Line Rate)
E: Exposure
Determined by the Exposure Time
Parameter or Register Setting
F: Exposure Overhead or
Exposure Overhead &
(at Least Partial) Readout